Placement
technique:
The
Dri-Angle has been contoured to fit the inside of the cheek.
Choose the small or large size for the particular patient. Place
the convex side against the cheek with the apex of the Dri-Angle as far
back as possible. The apex should almost touch the retro-molar
pad area.
Heavy salivators:
Use a double thickness of Dri-Angles or use the
silver coated Dri-Angle. The silver coating acts as a complete
moisture barrier to ensure absolute dryness.
Important:
If the Dri-Angle has not become saturated with
saliva, wet is thoroughly with a squirt of water before removing it
from the cheek. If the Dri-Angle is not thoroughly wet, it can stick to
the cheek and pull away tissue.
Dri-Angle as tongue
protector:
Dri-Angle can protect the tongue when preparing teeth in the lower
bicuspid and molar area. Have the patient extend the tongue and
place the tip of the tongue in the opposite buccal fold. Place a
small Dri-Angle against the tongue where it will adhere slightly and
give complete protection.
|
|
|
©
Copyright 2005. Dental Health Products, Inc. All rights reserved.
|